WaveForms™ SDK Reference Manual
Page 80 of 85
11 Deprecated functions
The following functions are replaced by FDwfAnalogOutNode *providing access to the Amplitude and Frequency
Modulation of Analog Out channels.
FDwfAnalogOutPlayStatus(HDWF hdwf, int idxChannel,
int *cdDataFree, int *cdDataLost, int *cdDataCorrupted)
Parameters:
- hdwf Open interface handle on a device.
- idxChannel Channel index.
- cdDataFree Pointer to variable to return the available free buffer space, the number of new samples that can
be sent.
- cdDataLost Pointer to variable to return the number of lost samples.
- cdDataCorrupted Pointer to variable to return the number of samples that could be corrupted.
The function above is used to retrieve information about the play process. The data lost occurs when the device
generator is faster than the sample send process from the PC. In this case, the device buffer gets emptied and
generated samples are repeated. Corrupt samples are a warning that the buffer might have been emptied while
samples were sent to the device. In this case, try optimizing the loop for faster execution; or reduce the frequency
or run time to be less or equal to the device buffer size (run time <= buffer size/frequency).
FDwfAnalogOutPlayData(HDWF hdwf, int idxChannel, double *rgdData, int cdData)
Parameters:
- hdwf Open interface handle on a device.
- idxChannel Channel index.
- rgdData Pointer to samples array to be sent to the device.
- cdData Number of samples to send.
The function above is used to sending new data samples for play mode. Before starting the Analog Out instrument,
prefill the device buffer with the first set of samples using the AnalogOutDataSet function. In the loop of sending
the following samples, first call AnalogOutStatus to read the information from the device, then
AnalogOutPlayStatus to find out how many new samples can be sent, then send the samples with
AnalogOutPlayData.
FDwfAnalogOutEnableSet(HDWF hdwf, int idxChannel, BOOL fEnable)
Parameters:
- hdwf Open interface handle on a device.
- idxChannel Channel index.
- fEnable TRUE to enable, FALSE to disable.
The function above enables or disables the channel specified by idxChannel. With channel index -1, each Analog
Out channel enable will be configured to use the same, new option.
Przeglądanie stron 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85

Komentarze do niniejszej Instrukcji

Brak uwag

EarthQuake PH2200W.4 Handbücher

Bedienungsanleitungen und Benutzerhandbücher für Audioverstärker EarthQuake PH2200W.4.
Wir stellen 1 PDF-Handbücher EarthQuake PH2200W.4 zum kostenlosen herunterladen nach Dokumenttypen zur Verfügung Spezifikationen






Weitere Produkte und Handbücher für Audioverstärker EarthQuake

Modelle Dokumententyp
300W.2 Bedienungsanleitung   The New Lineup - Earthquakesound, 8 Seiten
XJ-600R Spezifikationen   EarthQuake XJ-600R Specifications, 12 Seiten
Nova PA-600 Operation manual Bedienungsanleitung   FEI Helios NanoLab 600i SEM/FIB DualBeam Workstation, 11 Seiten
Cinenova-16 Betriebsanleitung   EarthQuake Cinenova-16 Operating instructions, 16 Seiten
300W.2 Bedienungsanleitung   Operating Manual for API 200W, 300W, 500W and [en] , 11 Seiten
Cin'enova IR16 Bedienungsanleitung   EarthQuake Cin'enova IR16 User`s manual, 20 Seiten
300W.2 Spezifikationen   EarthQuake 300W.2 Specifications, 62 Seiten